Third-Party Design Vetting and Proof Checking
Independent checks of structural and mechanical designs by FEA and code calculation, before fabrication or before submission to an authority or lender.

What this solution covers
A design is usually checked by the same team that made it. Owners, EPC contractors, lenders and authorities often want a second, independent opinion before steel is cut or a drawing is approved. Shirsh Technosolutions provides that check for structures and mechanical components.
We review the design basis and rebuild the critical parts of the analysis in ANSYS Mechanical. Members, connections and foundations are then checked against the governing code, whether that is IS 800, IS 801, IS 875, ASCE 7, Eurocode or ASME. The client gets an item-by-item report saying what passes and what has to change.
Pain points we address
The owner has no in-house team to check a supplier's or contractor's design
Lender or independent engineer comments are holding up the project
Plan-check comments need a calculated reply before approval
The design looks heavy, and nobody can say whether the extra steel is needed
Nobody is sure the right code and load combinations were used
What we solve
Review of design basis reports, calculations, analysis models and drawings
Independent re-analysis of critical members and connections
Wind and seismic load checks to IS 875, IS 1893 and ASCE 7
Member, connection and base plate checks to IS 800, IS 801 and the relevant overseas codes
Calculated replies to independent engineer and plan-check comments
Re-checks of the revised design until every item closes
How we approach it
- 1
Agree the scope, the governing codes and the documents to review
- 2
Review the loads, load combinations, materials and supports
- 3
Rebuild the critical analysis independently instead of re-running the designer's model
- 4
Check members, connections, base plates and foundations against code limits
- 5
Issue observations marked as complied, not complied or needing clarification
- 6
Review the revised design and close each observation
Deliverables
Vetting report with item-by-item observations
Independent analysis results for the critical items
Marked-up drawings and calculation comments
Replies to independent engineer or plan-check comments
Closure report on the revised design
Expected outcomes
An independent opinion that owners, lenders and authorities can rely on
Errors found on paper, before fabrication or erection
Reviewer comments closed with calculation
A calculated basis for lightening a design that turns out to be conservative
Why Shirsh
We design the same kinds of structures ourselves, so we know where designs usually go wrong, such as a missed load combination or a support modelled stiffer than it really is. Solar mounting structures and trackers make up most of this work. We have also certified storage racking and verified parking structures. When an independent engineer or plan checker raises comments, we answer them with calculation and stay on the job until every point closes.
Where this lives
Want to learn this?
We also offer ANSYS & SolidWorks training courses.
At a glance
Discuss your project with our engineers
Tell us about your simulation, validation or design challenge.