EN 12663 and IEC 61373: Which Load Case Sizes an Equipment Bracket

A rail equipment bracket that is comfortable at 3 g can still be sized by the IEC 61373 vibration test. We ran a generic underframe bracket in three section sizes to see when the random test governs, and why the bracket's natural frequency decides it.

A
Amit Nirmal
27 November 2026

Read the full article below for the methodology, the data, and the engineering decisions behind it.

Equipment hung under a railway vehicle, say a converter case or an oil cooler, usually comes with two documents attached to its bracket design. EN 12663-1 gives the static accelerations the attachment has to carry. IEC 61373 gives the random vibration and shock tests the equipment has to pass. Bracket calculations often take the first, show a stress well under yield at 3 g, and treat the second as the supplier's problem on the shaker table.

The two documents describe very different loadings, and which one sizes the bracket depends on something neither of them states as a number for your part: the natural frequency of the bracket with the equipment on it. We ran a generic bracket arm in three section sizes to show how far the answer moves.

1. What each document asks for

EN 12663-1 (railway vehicle bodies, locomotives and passenger rolling stock) treats equipment attachments in three places: clause 6.5.2 for the proof load cases, clause 6.7.3 for fatigue loads at the attachment interface, and clause 6.9.2 for modes of vibration of equipment. The proof cases are static accelerations applied to the equipment mass one direction at a time. The vertical case is written as (1 ± c) g, where c is 2 at the vehicle end and falls linearly to 0.5 at the vehicle centre, so the same box needs a bracket good for 3 g downward at the end of the car and 1.5 g at mid-length. The same structure, with longitudinal ±5 g, transverse ±1 g and this vertical c, is set out in EN 12663-2 clause 5.2.4.2 for freight wagons. Fatigue at the attachments is assessed for 107 cycles of smaller accelerations.

IEC 61373:2010 is a test standard. It sorts equipment by where it sits: Category 1 body mounted (Class A directly on or under the car body, Class B inside an equipment case that is itself on the body), Category 2 bogie mounted and Category 3 axle mounted. Each axis gets a functional random vibration test and a simulated long-life random test at amplified levels. Shocks are applied separately. The long-life vertical level quoted for body-mounted equipment is 5.72 m/s² r.m.s. over 5 to 150 Hz, held for 5 hours per axis. The amplified level is the standard's way of compressing service life into a few hours on the shaker.

So one document gives you a g value to multiply by mass. The other gives you an input spectrum at the bracket root, and what reaches the equipment depends on how the bracket responds to it.

2. The worked check

We took a generic 120 kg equipment box carried on two cantilever arms from an underframe crossmember, 60 kg per arm, with the load point 250 mm from the crossmember face. The arm is a square hollow section in one of three sizes: A, 30 × 30 × 3 mm; B, 50 × 50 × 3 mm; C, 100 × 100 × 6 mm. Steel throughout, E = 200 GPa.

Each arm was modelled as a solid in scikit-fem, the open-source finite element library, with 27-node bricks and full integration, fixed at the crossmember face, the 60 kg lumped over the tip face. The model gives the static stress for 1 g and the first natural frequency of the arm with its mass: 25.0 Hz for A, 54.0 Hz for B and 165.6 Hz for C. For the nominal bending stress at the root we read the top-fibre stress 25 mm and 62.5 mm from the crossmember and extrapolated to the root section: 55.51 MPa per g for A, 17.65 MPa for B and 2.18 MPa for C. At 25 mm the model agrees with simple beam theory to within 0.2% on A and B.

Generic underframe equipment box on two square hollow section arms, and arm B in the solid model coloured by bending stress at 1 g

The generic arrangement and arm B in the solid model, coloured by bending stress at 1 g, deflection drawn 300 times larger. Computed for this article.

For the random test we treated each arm as a single mode with 5% of critical damping and applied the 5.72 m/s² r.m.s. vertical level as a flat spectrum from 5 to 150 Hz, 0.2256 (m/s²)²/Hz. That is a simplification. The standard's spectrum is not flat, and for a real check its own breakpoints should be used. We used the full single-mode response rather than Miles' equation, which assumes a flat input around the resonance and is discussed in our earlier note on random vibration checks. The response was integrated over the band and converted to an equivalent quasi-static acceleration on the arm, so that it can be compared directly with the proof cases in g.

3. Which case sizes the bracket

The comparison below is for the vertical direction only. "Random test, 1 g + 3σ" adds gravity to three standard deviations of the dynamic response, the usual way a random load is turned into a design value.

Arm

First mode, Hz

Proof, vehicle centre (1.5 g), MPa

Proof, vehicle end (3 g), MPa

Random test, 1 g + 3σ

Random test, MPa

Random vs end proof

A, 30 × 30 × 3

25.0

83.3

166.5

3.86 g

214.2

1.29 ×

B, 50 × 50 × 3

54.0

26.5

52.9

5.22 g

92.1

1.74 ×

C, 100 × 100 × 6

165.6

3.3

6.5

4.26 g

9.3

1.42 ×

On all three arms the long-life test, read this way, asks more of the bracket than the 3 g end-of-car proof case. On arm B, with its mode in the middle of the test band, it asks for 5.22 g against 3 g. If the same box sits at mid-length, where the proof case is only 1.5 g, the ratio is about 3.5.

A bracket that does not respond at all would see 1 g plus three times the input, 0.583 g r.m.s., which is 2.75 g. That is close to the end proof case already. Every bit of resonance in the band pushes it past.

Equivalent vertical acceleration under the long-life random test against bracket natural frequency, compared with EN 12663 proof levels

Equivalent vertical acceleration on the arm under the long-life random test (1 g + 3σ) against the arm's natural frequency, for 2%, 5% and 10% damping, with the EN 12663 vertical proof levels for comparison. Input spread flat over 5 to 150 Hz. Computed for this article.

Two things in that figure matter for design. The first is damping. For arm B, 2% damping gives 7.68 g and 10% gives 3.97 g, from the same input. Damping in a bolted steel bracket is rarely measured before the test, so a design that only passes at 10% is a guess. The second is the band edge. Arm C, at 165.6 Hz, is outside the 5 to 150 Hz band and still reaches 4.26 g in this calculation, because the top of the band is close enough to its resonance to be amplified. Putting the first mode "above the band" needs real margin above 150 Hz, and with the standard's actual spectrum shape the answer near the top of the band will differ from our flat spread, so this is where the real spectrum must be used.

4. Three sigma is not the largest peak in five hours

A 3σ value is exceeded about 0.3% of the time for a Gaussian response, which is many times in a five-hour test. For a narrow-band response, the expected largest peak over N cycles is roughly the square root of 2 ln N times σ. Arm B at 54.0 Hz goes through about 973,000 cycles in 5 hours, which gives a factor of 5.25 rather than 3. The expected largest peak then corresponds to 8.38 g, or 148.0 MPa at the root, against 92.1 MPa at 3σ. For arm A, with 449,000 cycles, the factor is 5.10 and the root stress reaches 325.4 MPa, close to the yield of an S355 section.

Those same cycles matter for fatigue. EN 12663-1 assesses attachment fatigue at 107 cycles of small service accelerations. The long-life test puts close to a million cycles into arm B on each axis, at an r.m.s. of 1.406 g equivalent, which is 24.8 MPa r.m.s. at the root in this model. Whether the root weld survives that is a fatigue calculation with the weld detail category, not a static check, and it is worth doing before the test rather than after it.

Shock behaves differently. For a 30 ms half-sine pulse, the duration used for body-mounted shock testing, the arms see the pulse multiplied by 1.64 (A), 1.37 (B) and 1.04 (C). A long pulse relative to the bracket period is close to quasi-static, so shock seldom governs a body-mounted bracket unless the bracket is soft.

5. Where the peak sits, and a mesh check

The largest stress in every solid model sits at a corner of the root face, where the fixed boundary meets the section wall. That is a singular point. On arm B it rose from 34.7 to 42.6 to 47.2 MPa per g as the mesh went from 400 to 1,120 to 2,640 elements, and would keep rising. The quantities used above did not move: the first mode went from 54.29 to 54.04 to 53.86 Hz, and the nominal root stress from 18.05 to 17.65 to 17.65 MPa per g. For a welded root, the nominal or structural hot-spot stress is what goes into a fatigue class, and the corner value of a fixed-face model is not that.

The solid model is also softer than beam theory on the stubby arm C, 73,593 N/mm against 128,097 N/mm, because shear and local wall flexibility matter when the arm is only 2.5 section depths long. A beam model would have placed arm C at about 230 Hz, comfortably clear of the band. The solid model puts it at 165.6 Hz.

6. Reading the load cases right

A practical sequence for an underframe or roof-mounted equipment bracket:

  • Confirm the IEC 61373 category and class with the equipment supplier, and where on the car body the equipment sits, so that c in the EN 12663 vertical case is taken at the right position.

  • Get the first modes of the bracket with the equipment mass on it before sizing anything. If a mode falls inside the test band, the random test will very likely govern, and a 3 g static check says little.

  • Run the random response with the standard's own spectrum, in each axis, with a damping value you can defend, and report both 3σ and the expected peak over the test duration.

  • Check the root welds and bolts in fatigue against the test cycles as well as the EN 12663 fatigue accelerations.

  • Report stresses at the weld or bolt detail, not at a fixed-face corner.

Our example covers the vertical direction and one generic geometry. The lateral and longitudinal directions need the same treatment, and on many real brackets the weak axis is one of those.

Where Shirsh fits

At Shirsh Technosolutions we run strength, modal, random vibration and fatigue checks for rolling stock and defence equipment mountings to EN 12663 and IEC 61373, in ANSYS Mechanical and in open-source codes such as CalculiX and Code_Aster. If you have a bracket that passes on paper at 3 g but has not yet seen a shaker, or a test failure you want to understand before the next one, please get in touch.

References: EN 12663-1:2010+A1:2014, clauses 6.5.2, 6.7.3 and 6.9.2; EN 12663-2:2010, clause 5.2.4.2 and Tables 10 to 12; IEC 61373:2010, clauses 1 and 4 (categories and test purpose). The long-life r.m.s. level, band and duration used here should be checked against Table 2 of the reader's own copy of IEC 61373 for the category and class in question.

Visual Summary