Back to Insights
8 min read

Theta-JA on Small Boards: Why the JEDEC Number Runs Cool

A datasheet θJA is measured on a JEDEC test board, and that board does most of the cooling. We put the same footprint and the same 2s2p copper on 40 mm and 25 mm boards and the board-side resistance rose from 17.7 K/W to 38.1 and 84.5 K/W, with the air side mattering more than the copper.

A
Amit Nirmal
23 November 2026

Read the full article below for the methodology, the data, and the engineering decisions behind it.

Most board-level thermal estimates still start from the θJA line in a package datasheet: power times θJA plus ambient, and the junction temperature looks comfortable. That number was measured on a JEDEC test board, a specific piece of FR-4 with specific copper, sitting in still air. A compact product board shares the package and very little else. This note looks at what the JEDEC documents and vendor application notes say θJA is for, and then puts numbers on the difference with a small conduction model of three boards solved in scikit-fem.

1. What the datasheet number actually measures

θJA is measured with the package soldered to a standard test board in the JESD51-2A still-air enclosure. Renesas TB379 describes these tests as run "in a 1 cubic foot box", with the board horizontal and the device on top. The high-conductivity board most datasheets now quote (JESD51-7, usually called 2s2p) is about 1.6 mm of FR-4 with 2 oz surface traces and two buried 1 oz solid copper planes; for packages up to 27 mm the board is 3 by 4.5 inches (76.2 by 114.3 mm) with planes 2.92 inches (74.2 mm) square. The older low-conductivity board (JESD51-3, 1s) has the surface traces only.

The vendors are plain about what follows from this. TI's SPRA953 states that RθJA "is not a characteristic of the package by itself", calls its use to estimate junction temperature in an application a misapplication, and notes that in still-air JEDEC tests roughly 70% to 95% of the chip power leaves through the test board. In effect the board is the heat sink. TI reports as much as a 50% variation in RθJA from 1s versus 2s2p board construction alone, and Renesas puts the reduction from adding the two planes at roughly 20% to 40% or more depending on package. If the board can move the number that much between two JEDEC boards, a product board that is smaller than both deserves a look of its own.

2. The check we ran

We modelled only the board side of the path: a 7 × 7 mm package footprint putting 1 W uniformly into a board, heat spreading in the plane of the board, and heat leaving both faces to still air. The in-plane conductance of each board is the sum of its layers: FR-4 at an assumed 0.8 W/m·K in-plane over 1.6 mm, plus 35 µm copper planes at 390 W/m·K where the planes exist. For the 2s2p stack that gives 0.0286 W/K, and the copper carries 95.5% of it. Each face loses heat with a combined coefficient h of 10 W/m²K; radiation alone, linearised at 25 °C with an emissivity of 0.9, is about 5.4 W/m²K, and still-air convection adds a similar amount. We also ran 5 and 15 W/m²K to see how much the answer leans on this choice.

The three boards carry the same 2s2p copper: board B is JEDEC-size at 76.2 × 114.3 mm with 74.2 mm planes, board C is 40 × 40 mm, and board D is 25 × 25 mm, each with planes 1 mm short of the edge. The result we report is the average temperature rise over the package footprint per watt, a board-to-ambient resistance. Junction-to-board resistance inside the package comes on top of it and is the same on every board. Refining the mesh on board B from 1.0 mm to 0.25 mm moved the result from 17.67 to 17.73 K/W. As a check against theory, a 500 mm square plate with full planes gave 14.50 K/W against 14.67 K/W from the closed-form solution for a circular source of the same area on an infinite plate; the 1.1% gap is mostly the square footprint drawn as a circle.

3. What the boards do

Board

Size, mm

Copper

h = 15 W/m²K

h = 10 W/m²K

h = 5 W/m²K

B

76.2 × 114.3

2 planes

15.1 K/W

17.7 K/W

24.6 K/W

C

40 × 40

2 planes

27.6 K/W

38.1 K/W

69.4 K/W

C, one plane

40 × 40

1 plane

44.2 K/W

D

25 × 25

2 planes

57.8 K/W

84.5 K/W

164.5 K/W

Same package, same copper, same air: the 40 mm board has 2.15 times the board-side resistance of the JEDEC-size board, and the 25 mm board 4.77 times. At 1 W that is 20.4 K and 66.8 K of extra rise that no datasheet θJA can show, whichever package is fitted.

Computed temperature rise per watt on a JEDEC-size, a 40 mm and a 25 mm two-plane board

Computed temperature rise per watt on the three boards at h = 10 W/m²K per face, drawn to the same scale and the same colour range. The cyan square is the 7 × 7 mm package footprint. Generic boards computed for this note.

4. Why copper stops helping on a small board

A thin plate cooled on both faces has a natural spreading length, the square root of its in-plane conductance over 2h. For the 2s2p stack at 10 W/m²K that length is 37.8 mm. On board B the edges sit 38 to 57 mm from the package, at or beyond this length, so the heat fades out before it reaches them and the copper does the work. On boards C and D the edges are only 20 and 12.5 mm away, the planes run fairly flat in temperature, and the limit becomes plain surface area: 1/(2hA) is 31.3 K/W for the 40 mm board and 80.0 K/W for the 25 mm board, against 38.1 and 84.5 K/W computed. That is why taking one plane out of board C only raises it from 38.1 to 44.2 K/W, while halving h from 10 to 5 W/m²K raises it by 82%. On the JEDEC-size board the same change in h costs 39%, and on board D it costs 95%.

The practical reading is that on a small board the air side matters more than the copper. A sealed plastic housing, a board mounted vertically against a wall, or a neighbouring board a few millimetres away all change h, and the small board follows h almost one for one.

Bar chart of board-to-ambient resistance for three board sizes at three surface coefficients

Board-to-ambient resistance for the same footprint and 2s2p copper at three surface coefficients. Computed for this note; package-internal resistance not included.

5. What to use instead

The same documents point to the better tools. ΨJT and ΨJB are characterisation parameters, not true resistances: TJ = TT + ΨJT × P from a measured package-top temperature, or TJ = TB + ΨJB × P from the board temperature next to the package. Because most of the heat does not cross the package top, ΨJT is small and much less sensitive to the board than θJA, which makes it useful for checking a prototype with a fine thermocouple. TI cautions that ΨJT should not be used once a heat sink is fitted. For design before hardware exists, the board itself has to be modelled with its real size, copper and air side, which is a short conduction or CFD job rather than a datasheet line.

The model here leaves out through-thickness resistance and vias, traces outside the planes, the package's own top-surface cooling and other heat sources on the board, all of which a real study would include. The trend it shows does not depend on them.

Where Shirsh fits

At Shirsh Technosolutions we model electronics boards and enclosures with ANSYS Icepak and ANSYS Mechanical, from a quick board-spreading check like this one to full enclosure CFD with the real stack-up, vias and heat sinks. If you have a compact board or a sealed housing where the junction margin looks thin, please get in touch.

References

Texas Instruments, SPRA953D, Semiconductor and IC Package Thermal Metrics (December 2003, revised March 2024): section 1 (RθJA not a characteristic of the package by itself; best used to compare packages), 1.1 (use to estimate TJ is a misapplication; 70% to 95% of power through the test board in still air), 1.2 (up to 50% RθJA variation from 1s versus 2s2p), sections 3 and 5 (ΨJT, ΨJB).

Renesas (Intersil) TB379, Thermal Characterization of Packaged Semiconductor Devices, Rev. 4.00 (August 2015): still-air tests in a 1 cubic foot box; typical test board features (FR-4, 2 oz surface traces, 1 oz buried planes, about 1.6 mm); board sizes by package size; adding two planes lowers θJA roughly 20% to 40% or more; ΨJT and ΨJB usage.

JEDEC JESD51-2A (natural convection environment), JESD51-3 (low effective thermal conductivity test board), JESD51-7 (high effective thermal conductivity test board), JESD51-12 (guidelines for reporting and using package thermal information).

Worked check computed for this note on 23 November 2026: steady 2D conduction in the plane of the board, −∇·(kt ∇T) + 2hT = q, solved with scikit-fem 12.0.2 on linear triangles (0.5 mm grid, about 36,600 nodes on board B), adiabatic edges; kt = 0.8 × 1.6 mm (FR-4, assumed) + n × 390 × 0.035 mm (copper planes); 1 W uniform over a 7 × 7 mm footprint; result is the footprint-average rise per watt. Closed-form check for a circular source on an infinite plate: average rise q/(2h) × [1 − 2 I1(ma) K1(ma)], m = (2h/kt)^0.5. Generic boards; not any product.

Visual Summary

Click to view full size

See it in practice

Related case studies

Want to Apply This to Your Product?

Our engineers can help you implement these techniques on your specific components and assemblies.

Get insights like this in your inbox

Engineering deep-dives, simulation tips, and industry analysis. No spam, unsubscribe any time.