Solar Street Light Pole Wind Load FEA to IS 875: Redesign Through Design Iterations
Solar street light pole wind load FEA to IS 875-3 in ANSYS Mechanical: high stress and sway found, pole and panel frame revised until stresses held.

Project brief
A solar energy company was developing a solar street light with two PV modules on top, two luminaires on arms and two batteries on a stand partway up the pole. Before releasing it, the design team wanted to know whether the pole, the panel frame and the brackets would survive the design wind speed for the sites, with an extra battery load on the stand. They sent us the 3D model and asked for a structural check.
Shirsh Technosolutions ran a solar street light pole wind load FEA in ANSYS Mechanical, with the wind pressure worked out to IS 875 Part 3. The first design did not pass. Stress went above yield at the panel frame clamp and the top of the pole swayed a lot. We shared marked-up results, the client revised the pole and the frame, and we re-ran the model on every version until the stresses came back below yield. The final report gave stress, shear and deflection for the whole structure and the base reactions for the foundation.
What was at risk
A solar street light looks simple, but it is a tall, slender cantilever with a large sail on top. The two modules catch the wind, and all of that load comes down through one clamp and one pole to the base. The luminaire arms and the batteries add weight high up and at mid-height, so the pole sees bending from the wind on top of its own self-weight and equipment loads.
The client had a full 3D design but no check of it against the code wind. Hand calculation of the pole alone would miss what happens at the clamp, the bracket plates and the ladder-type panel frame, where the load changes direction and stress concentrates. The design team also wanted answers fast, and every design change had to be checked again on the full assembly.
Solution offered
Wind load to IS 875 Part 3. We worked out the design wind speed from the basic wind speed with the risk, terrain and topography factors, then the design wind pressure, and applied it on the module surfaces with an external pressure coefficient. The governing case was wind lifting the panels from below, combined with self-weight.
Full assembly model. The client's 3D model was meshed in ANSYS Mechanical with shell elements for the pole, frame and brackets. Connections were modelled as bonded or bolted following the drawing. The luminaires and the batteries were added as point masses at their mounting points, and the pole was fixed at the base. Structural steel to IS 2062 / IS 1239 was used, with the working stress approach of IS 800.
Iterate with the design team. The first run showed stress above yield at the clamp between the panel frame and the pole top, and a large sway at the top. We sent the plots with the hot spot marked. The client changed the pole section and upsized the bolts; our next run moved the peak stress down to the battery mounting and still showed the upper frame moving too much, so we suggested stiffer brackets. In the next version the pole was changed again and supports were added under the module frame. That version brought every member below yield.
Report the whole picture. For the final design we reported equivalent stress, shear stress and deflection for the full structure, the pole and the frame separately, and the reaction forces at the base for the foundation designer. Deflection at the top was flagged in the results so the client could decide on it with the stress check in hand.
Common questions
How is wind load on a solar street light calculated to IS 875?
The basic wind speed is multiplied by the risk, terrain-height and topography factors (k1, k2, k3) to get the design wind speed. The design pressure is 0.6 times its square, and it is applied on the module area with a pressure coefficient, usually as uplift and as downward wind.
Why use FEA for a solar street light pole instead of a simple cantilever check?
A cantilever calculation gives the bending at the base of the pole. FEA of the full assembly also shows stress at the panel clamp, the bracket plates and the battery mounting, and the real sway of the head. In this project the first failure was at the clamp, which a pole-only check would not show.
Challenges we overcame
A slender pole carrying two modules, two luminaires and two batteries
Wind uplift on the panels combined with equipment weight high on the pole
Stress above yield at the clamp between the panel frame and the pole top
Large sway at the head of the pole
Peak stress moving to a new location after each design change
Quick re-checks of every revised design on the full assembly
How we executed
- 1
Reviewed the client's 3D model, the equipment loads and the design wind speed
- 2
Worked out the design wind speed and pressure to IS 875 Part 3
- 3
Meshed the pole, panel frame and brackets with shell elements and modelled bonded and bolted joints
- 4
Added luminaires and batteries as point masses and fixed the pole at the base
- 5
Solved the wind uplift plus self-weight case and found the stress hot spot and the sway
- 6
Shared marked-up results and re-ran each revised pole and frame from the client
- 7
Confirmed the final design with all members below yield and shear in check
- 8
Issued the report with stress, shear, deflection and base reactions
Project outcome
The weak point of the first design, the panel frame clamp at the pole top, found before the product went to site.
Four design versions checked on the full assembly, with the hot spot and sway marked each time.
Final pole and panel frame with all members below yield and shear stress within the limit used.
Peak stress moved away from the clamp, and sway at the head brought down from the first design.
Base reactions handed to the client for foundation design.
Project gallery
Where this lives
Software used
Related solutions
Industries
At a glance
We apply the same rigour to every engagement
Let us show you what's possible for your product.