Saddle Heat Loss CFD for an Insulated Waste Heat Boiler in Sub-Zero Wind
Conjugate heat transfer CFD in ANSYS Fluent to find heat lost through the bare saddles of an insulated Claus waste heat boiler in cold winter wind.

Project brief
A boiler and heat-recovery equipment fabricator was building a Claus waste heat boiler for the sulphur recovery unit of a refinery in a cold climate. The boiler shell is fully wrapped in mineral wool, but the two saddles that carry it are not. They are bare steel with only a fire-proofing coating, and in a hard winter wind they act like fins pulling heat out of the shell. The fabricator needed a credible number for how much heat leaves through the saddles before the design went to its customer.
Shirsh Technosolutions answered this with a saddle heat loss CFD study in ANSYS Fluent. We built a conjugate heat transfer model of the boiler shell, insulation, saddles, coating and PTFE base pads inside a large air domain, ran it at two wind speeds and closed a face-by-face heat balance on each saddle to report the loss to atmosphere.
What was at risk
On an insulated vessel the saddles are the weak spot. The steel saddle plate sits right against the warm shell, the saddle itself pokes out below the insulation, and the cold air sweeps across its web and ribs. How much heat escapes this way depends on the wind, on the coating, on what sits under the base plate and on how the insulation wraps the saddle top. A hand calculation with a guessed film coefficient cannot capture all of that together.
There were details that mattered. One saddle is fixed and the other slides, so their base build-ups were different, with PTFE pads acting as thermal breaks over the supporting steel structure. And because the boiler is long, a wind blowing along its axis would not be the worst case, so the flow direction had to be chosen with care.
Solution offered
One model for the solids and the air. We set up a conjugate heat transfer CFD model in ANSYS Fluent, so conduction through the steel, insulation, coating and PTFE was solved together with convection into the moving air. The geometry included the boiler shell, the full mineral wool wrap, both saddles with their fire-proofing coating, and the base pads on each saddle, all placed inside an air domain with a symmetry plane to keep the cell count sensible.
Material and boundary data from the client. Each solid got its own thermal conductivity, with the shell steel conductivity varying with temperature. Air density followed the incompressible ideal gas law so buoyancy near the warm surfaces was not lost. The shell temperature was fixed from the process data and the incoming air was set at the site winter design temperature.
Wind set across the boiler, not along it. After the first review the client pointed out that a long vessel sees its worst wind across or at an angle to its axis. The model was turned so the wind approaches the boiler obliquely, and the study was run at two wind speeds for a steady, turbulent, incompressible flow with energy.
Mesh built for thin layers. A poly-hexcore mesh was used, with fine cells through the thin coating and PTFE layers and around the saddle-to-shell contact. Mesh quality was checked before the runs.
A heat balance you can audit. For each saddle the surfaces were split into named regions: the face in contact with the shell, the exposed top edges, the web and ribs, and the base. Heat flux and area were integrated on each region, so the heat coming in from the shell could be checked against the heat leaving to air and to the support, and the net balance on every saddle closed to a negligible residual.
Design updates folded in. When the fabricator changed the fixed saddle base to a plain PTFE pad, the model was updated and both wind cases were re-run before the final report.
Common questions
How do you calculate heat loss through the saddle of an insulated vessel? The most reliable way is conjugate heat transfer CFD. The shell, insulation, saddle, coating and base pads are modelled as solids inside the surrounding air, the wind and site temperatures are applied, and the heat flux is integrated over each exposed saddle face. This captures conduction and wind-driven convection together, which a hand calculation with an assumed film coefficient cannot.
Does wind direction matter for heat loss from a long horizontal vessel? Yes. Wind blowing along the axis of a long boiler is partly shielded by the vessel itself. Wind across the vessel or at an angle hits the saddles more directly and strips more heat from their webs and ribs, so the oblique or crosswind case is the one to report.
Challenges we overcame
Bare saddles under a fully insulated boiler in sub-zero wind
Thin coating and PTFE layers that still control the heat path
Different base build-ups on the fixed and sliding saddles
Light winds where buoyancy near warm surfaces still counts
Worst-case wind direction on a long horizontal vessel
A loss figure the fabricator could defend to its customer
How we executed
- 1
Took the boiler GA, saddle details and site design data from the fabricator
- 2
Built the shell, insulation, saddles, coating and base pads as solids
- 3
Placed the boiler in an air domain with a symmetry plane
- 4
Meshed with poly-hexcore cells, fine through the thin layers
- 5
Assigned solid conductivities and ideal-gas air properties
- 6
Ran steady conjugate heat transfer at two wind speeds with oblique wind
- 7
Integrated heat flux on each named saddle face and closed the heat balance
- 8
Updated the fixed saddle base and re-ran before the final report
Project outcome
Total heat loss through both saddles reported for each wind speed.
Heat balance closed on the fixed and the sliding saddle, face by face.
Most of the loss traced to the exposed web and ribs, very little through the PTFE base.
Stronger wind shown to raise the saddle loss noticeably.
Fabricator accepted the result and asked for the final signed report.