Context

Project brief

An automated car parking system maker was supplying a puzzle parking system for an export project in the United States. The system stacks cars on movable pallets in levels above the ground and in a pit below it, shuffling them sideways and lifting them up and down to bring any car to the entry level. The steel structure had to be shown stable under the local wind and earthquake loads, and the support loads were needed for the anchorage design.

Shirsh Technosolutions carried out puzzle parking structural analysis in ANSYS Mechanical. Wind and seismic loads were set up to ASCE 7-10 with IBC 2015 seismic site data, combined using the ASCE 7-10 allowable stress design combinations, and checked against allowable stresses for each steel grade. The pallets, lifting assemblies and shifting trolley were checked in their own models, and support reactions were reported for the anchorage design.

The problem

What was at risk

A puzzle parking frame is a light steel structure that carries a lot of moving mass. Every level holds pallets, drive motors, chains and the cars themselves, and in an earthquake all of that mass pushes sideways on slender columns and bracing. The site for this system was in a zone of high seismicity, so the seismic case was going to drive the design.

The over-ground part also stands in the open wind, while the pit part sits below grade and sees only gravity and earthquake loads. Both had to be shown safe with cars parked off-centre on the pallets, and with the vertical part of the earthquake added to the dead load.

The design was not frozen either. During the work the structure members were revised, a crash barrier was added and the shifting pallet was changed. Later the load basis itself was moved fully onto ASCE 7-10. Each change meant a re-run of the whole model.

Our answer

Solution offered

Code loads set up first. Wind pressures on the over-ground frame were worked out to ASCE 7-10 for the site exposure, with windward, leeward and side wall coefficients. Seismic design parameters were taken from the USGS design maps for the site under ASCE 7-10, and the vertical seismic effect was added to the dead load as the code requires. Horizontal seismic accelerations were applied in both plan directions.

A frame model that carries the right mass. We modelled the steel frame of the above-ground unit and of the pit unit and meshed it in ANSYS Mechanical. The platforms were not meshed in detail. Their stiffness was represented by springs and their weight, with the lifting assemblies, trolleys and motors, came in as point masses and remote forces at the actual attachment points. The frame mass was increased to account for small parts that were not modelled, and the car loads were placed with a lateral offset to allow for a car parked off-centre.

Allowable stress design combinations. Load combinations followed ASCE 7-10 section 2.4 for allowable stress design: dead load alone, with cars, with wind and with seismic load in each direction, plus the reduced dead-load cases that check uplift and overturning. Hot-rolled and cold-formed sections were given their own yield strength and allowable stress.

Moving parts checked separately. The top lifting pallet, the shifting trolley, the shifting pallet with its lifting frame and the two-level pit pallet assembly were each analysed under a parked car, so the parts that carry the car directly were covered as well as the main frame.

Anchor reactions for the foundation design. For the governing combination on each unit, the force reactions at every wall and column support were tabulated in three directions, ready for anchor and foundation design.

Revisions handled in the same model. When the members, crash barrier and shifting pallet changed, and again when the load basis moved fully to ASCE 7-10, the model was updated and every combination was re-run, so the final report matched the system being built.

Common questions

How are seismic loads applied to a puzzle parking system in FEA? The site spectral values give the design acceleration. The frame mass, pallet and trolley masses and car loads are placed in the model, and horizontal accelerations are applied in each plan direction together with gravity. Under ASCE 7-10 the vertical earthquake effect is added by scaling the dead load up, and the ASD combinations then reduce the seismic share.

Why model the parking frame without detailed pallets? The pallets are stiff, compact parts and the frame is what sways in wind and earthquake. Representing the pallets as springs and point masses keeps the frame model fast enough to run every combination, and the pallets themselves are then checked in separate, detailed models under the car load.

The hurdles

Challenges we overcame

High-seismicity site where earthquake load drove the frame design

Heavy moving masses on slender columns and bracing

Wind on the above-ground frame and seismic-only loading in the pit

Cars parked off-centre on the pallets

Vertical seismic effect to be added to the dead load

Design changes and a change of load basis during the job

Methodology

How we executed

  1. 1

    Took the 3D models and weights of the frames, pallets, trolley and drives

  2. 2

    Worked out ASCE 7-10 wind pressures for the over-ground frame

  3. 3

    Took USGS seismic design parameters for the site to ASCE 7-10

  4. 4

    Built frame models with springs and point masses for the platforms

  5. 5

    Applied dead, car, wind and seismic loads with off-centre car positions

  6. 6

    Ran ASCE 7-10 allowable stress design combinations for both units

  7. 7

    Checked the lifting pallet, shifting trolley and pit pallets separately

  8. 8

    Reported support reactions and re-ran the model after each design change

Results

Project outcome

Over-ground and pit frames kept within the allowable stresses for both steel grades in every combination.

Lifting pallet, shifting trolley, shifting pallet and pit pallets checked under a parked car.

Wind and seismic design basis to ASCE 7-10 and IBC 2015 documented in the report.

Anchor reactions at every wall and column support handed over for foundation design.

Revised structure, crash barrier and new shifting pallet covered in the final report.