Wind Load FEA of FRP Camouflage Grills for Rooftop Telecom Poles to IS 875
Wind load FEA of FRP camouflage grills for rooftop telecom poles to IS 875-3 in ANSYS Mechanical, with IS 800 bolt checks approved by the owner's engineer.

Project brief
A telecom network owner was putting up rooftop poles in cities and wanted them screened, so that the antennas read as a decorative column and not a mast. The screens were perforated FRP grills, square and delta (triangular) in plan, made by an FRP fabricator in two heights each. Before approving them, the owner's project engineering team asked for calculations to show that the grills and their support frames would hold up in the design wind.
Shirsh Technosolutions carried out wind load FEA of the FRP camouflage grills in ANSYS Mechanical, with the wind pressure worked out to IS 875 Part 3 and the bolted joints checked to IS 800. We modelled each grill with its corner supports, brackets and connections to the central pipe, reported stress, shear and deformation, and turned the support reactions into bolt checks. Every report went through the owner's reviewer, and all four configurations were approved.
What was at risk
An FRP camouflage grill is a thin, heavily perforated shell standing on a rooftop, often on a support structure that lifts it well above the roof level. It catches the full wind on a large face, yet the material is a glass-filled composite, weaker and more flexible than steel, and the panels are full of cut-outs. The load has to pass through small bolted brackets to the roof and through corner supports to the central pole.
Two shapes made this harder. The square grill is a simple box but carries its load through bracing to the centre pipe. The delta grill flares out at the top, so the widest and most loaded part sits furthest from the supports. The owner wanted a documented check of stress in the FRP, the joints and the bolts for each shape and height, written in a form their engineers could review and sign.
Solution offered
Wind pressure to IS 875 Part 3. We worked out the design wind speed from the basic wind speed with the risk, terrain-height and topography factors, then the design pressure. Force coefficients for a square and a triangular section on a roof were taken from the code tables and the pressure was applied on the grill faces, together with self-weight.
Shell model of the whole grill. The fabricator's 3D models were meshed with shell elements in ANSYS Mechanical, keeping the perforation pattern so that load paths around the cut-outs were real. The grill panels, brackets, corner supports and top cover were connected as bonded or bolted joints following the supplied model. The FRP was described with its density, tensile strength, modulus, Poisson's ratios and shear modulus for a glass-filled laminate. Supports were placed at the base brackets and where the corner supports and top cover meet the central pipe.
Results the reviewer could follow. For each configuration we reported von Mises stress, maximum shear stress and total deformation for the full grill and for its parts, with the most stressed region shown close up. On the delta grills the peak sat in a very small local area of the panel, and the report stated that clearly so the reviewer could judge it.
Bolts and brackets to IS 800. Reaction forces at the base and at the corner supports were read from the model and shared between the bolts. Because FRP is weaker than the bolt steel, bearing of the bolt on the FRP governs, so we checked bearing strength to IS 800:2007 with the partial safety factor for bolts. The checks confirmed the bolt sizes and counts for the base and the grill-to-support joints, the shell thickness, and a thicker bottom bracket to cover gusts and bolt misalignment.
Review and correction. In the first delta submission the flared section had been taken at the bottom. The owner's engineer pointed this out, we re-modelled the grill with the flare at the top, re-ran it and added the taller delta version. The reviewer then asked for the conclusion to be reworded for both delta heights, and after that revision all four reports were approved.
Common questions
How is wind load on an FRP camouflage screen for a telecom pole calculated? To IS 875 Part 3, the basic wind speed is multiplied by the risk, terrain-height and topography factors to get the design wind speed, and the design pressure is 0.6 times its square. That pressure is multiplied by a force coefficient for the screen's plan shape (square or triangular) and applied on the exposed faces, with self-weight added.
Why check bolt bearing on the FRP and not just the bolt? In an FRP screen the composite is much weaker than the steel bolt, so the joint usually fails by the bolt bearing into the FRP and elongating the hole. The IS 800 bearing check uses the smaller of the two strengths, which here is the FRP, together with the plate thickness at the joint.
Challenges we overcame
Thin, perforated FRP shells catching full wind on a rooftop
A composite material weaker and more flexible than steel
Delta grills that flare out at the top, away from the supports
Load paths through small bolted brackets and corner supports to the central pipe
Bolt joints where bearing on the FRP governs
Four shapes and heights, each needing a report the owner's engineer could sign
How we executed
- 1
Took the fabricator's 3D models and the scheme drawings from the network owner
- 2
Worked out the design wind speed, pressure and force coefficients to IS 875 Part 3
- 3
Meshed each grill with shell elements, keeping the perforation pattern
- 4
Modelled bonded and bolted joints, FRP properties and the supports at base and centre pipe
- 5
Solved wind plus self-weight and reported stress, shear and deformation for each part
- 6
Read the support reactions and checked bolt bearing on the FRP to IS 800:2007
- 7
Re-modelled the delta grill with the flare at the top after the owner's review comment
- 8
Revised the conclusions as requested and issued all four reports for approval
Project outcome
Square and delta FRP camouflage grills in two heights each checked for the design wind.
All four reports reviewed and approved by the network owner's engineering team.
Bolt sizes and counts for the base and the grill-to-support joints confirmed by IS 800 bearing checks.
Shell thickness confirmed, and a thicker bottom bracket adopted for gusts and bolt misalignment.
Local stress peak in the delta grills identified and stated clearly for the reviewer's decision.
Delta grill orientation corrected in the model before approval, so the check matched the product.